WetlandMod | Sizing Options

The combination of horizontal flow and downward flow maximizes surface area and minimizes footprint. The WetlandMod™ is taking bioretention/biofiltration to a new level.

18″ Media – San Diego County Minimum Requirement

18″ Media Thickness WetlandMod Traditional Bioretention
Chamber Width I.D. (ft.) 4.00 4.00
Cage Width (ft.) 3.34 n/a
Void Width (ft.) 0.33 n/a
Chamber Height Max (TC) (ft.) 4.40 n/a
Assoc. Cage Height Max (ft.) 3.52 n/a
TC of Top of Cage Distance (ft.) 0.88 n/a
Ponding Over Media (ft.) 0.33 Variable
Chamber Height Min (ft.) 1.61 Variable
Assoc. Cage Height Min (ft.) 1.83 Variable
TC to Top of Cage Distance (ft.) 0.88 Variable

 

18″ Media Thickness WetlandMod Traditional Bioretention
MAX Surface Area Per Linear Foot (sq.ft.) 10.38 4
Footprint Reduction Provided  61%

 

18″ Media Thickness WetlandMod Traditional Bioretention
MIN Surface Area Per Linear Foot (sq.ft.) 7 4
Footprint Reduction Provided 43% 

24″ Media – Los Angeles County Minimum Requirement

24″ Media Thickness WetlandMod Traditional Bioretention
Chamber Width I.D. (ft.) 5.00 5.00
Cage Width (ft.) 4.34 n/a
Void Width (ft.) 0.33 n/a
Chamber Height Max (TC) (ft.) 4.40 n/a
Assoc. Cage Height Max (ft.) 3.52 n/a
TC of Top of Cage Distance (ft.) 0.88 n/a
Ponding Over Media (ft.) 0.33 Variable
Chamber Height Min (ft.) 2.05 Variable
Assoc. Cage Height Min (ft.) 2.33 Variable
TC to Top of Cage Distance (ft.) 0.88 Variable

 

18″ Media Thickness WetlandMod Traditional Bioretention
MAX Surface Area Per Linear Foot (sq.ft.) 11.38 5
Footprint Reduction Provided 56% 

 

18″ Media Thickness WetlandMod Traditional Bioretention
MIN Surface Area Per Linear Foot (sq.ft.) 9 5
Footprint Reduction Provided 44%