Flow Based Sizing

The MWS Linear can be used in stand alone applications to meet treatment flow sizing requirements. Since the MWS Linear is the only biofiltration system that can accept inflow pipes several feet below the surface it can be used not only in decentralized design applications but also as a large central end-of-the-line application for maximum feasibility.

Model # Dimensions WetlandMEDIA Surface Area Treatment Flow Rate (cfs)
MWS-L-4-4 4′ x 4′ 23 sq. ft. 0.052
MWS-L-4-6 4′ x 6′ 32 sq. ft. 0.073
MWS-L-4-8 4′ x 8′ 50 sq. ft. 0.115
MWS-L-4-13 4′ x 13′ 63 sq. ft. 0.144
MWS-L-4-15 4′ x 15′ 76 sq. ft. 0.175
MWS-L-4-17 4′ x 17′ 90 sq. ft. 0.206
MWS-L-4-19 4′ x 19′ 103 sq. ft. 0.237
MWS-L-4-21 4′ x 21′ 117 sq. ft. 0.268
MWS-L-6-8 7′ x 9′ 64 sq. ft. 0.147
MWS-L-8-8 8′ x 8′ 100 sq. ft. 0.230
MWS-L-8-12 8′ x 12′ 151 sq. ft. 0.346
MWS-L-8-16 8′ x 16′ 201 sq. ft. 0.462
MWS-L-8-20 9′ x 21′ 252 sq. ft. 0.577
MWS-L-8-24 9′ x 25′ 302 sq. ft. 0.693